Take care of your heating and cooling | Shanghai all mobile post blower anytime and anywhere!
2024-08-23

Every summer, everyone will sigh that the life is given by air conditioning, air conditioning, WiFi, watermelon become the three treasures of summer life。And for people who work outdoors or in special office Spaces, air conditioning is a luxury。The mobile post blower launched by Shanghai Zhongyou Industrial Co., Ltd. is dedicated to serving temporary or small areas requiring air supply places with reliable production...

  • 2015-03-10

    3-1 Cooling dehumidification cools the air below the dew point temperature, and the water vapor in the air condenses into water。The condensate can be removed and reheated to obtain low humidity air。The source of air cooling can be refrigerant, ice water or brine in the freezer。(1) If the surface temperature of the cooling coil is below 0 ° C, the condensate water is frozen on the surface of the coil, which reduces the cooling efficiency and dehumidification effect, so that stable humidity cannot be obtained。(2) In general use, the limit of cooling dehumidification is above the dew point temperature of 0 ° C。(3) If the equipment is large-scale, it will increase the power consumption and increase the operating cost。3-2 compression dehumidification method compresses and then cools the air, and the water vapor in the air condenses into water。The condensed water can be removed and reheated to obtain low-humidity air。空...

  • 2015-01-28

    See if it is leaking fluorine, should go to the after-sales check the use of dehumidifier precautions: 1.Microcomputer controlled dehumidifier, humidity sensor is a precision instrument, in the strong corrosive gas and large dust environment will lead to instrument failure.2.It does not have explosion-proof function, and it is strictly prohibited to use in the environment with special requirements such as flammable and explosive gas, dust, chemical products and biological products。3.Use on solid, flat ground to avoid noise caused by machine shaking.4.When using the machine, apply the power supply, and pay attention to whether the voltage of the power supply is consistent with the machine, do not use a socket with other electrical appliances.5.Do not use the machine near the heat source to avoid increasing electric energy.6.Do not use at temperatures higher than 38 ° C.7.In a moving or handling machine...

  • 2014-12-18

    Industrial dehumidifiers are mainly divided into two categories, (frozen dehumidifier, rotary dehumidifier) in the production and living environment, the relative humidity of the air has a decisive impact。The control and regulation of humidity is an important issue related to the production process and material storage。First, the importance of dehumidification: 1, corroded steel is not easy to rust when the relative humidity is less than 50%。Dehumidification is a more effective and cost-effective option for protecting your assets than applying bedliner。Examples such as Bridges, power stations, ships (during maintenance operations) and offshore buildings are typical dehumidification applications。2, condensation if the dew point temperature in the air is lower than the temperature of the surface of the object。There will be no condensation on the surface。Condensation can cause corrosion or electrical circuits...

  • 2014-11-29

    There are ZHONGYOU chiller commonly known as chiller, chiller, ice water machine, freezing machine, cooling machine water cooling machine mold chiller,Electroplating chiller and so on because of all walks of life are not the same, there are ZHONGYOU chiller classification in the refrigeration method can be divided into two categories: air-cooled chiller and water-cooled chiller,The biggest difference between the two is the cooling method,structurally,Their condensers are also different,They are shell tube type and fin type respectively。The water-cooled chiller must rely on the cooling water tower to work, and the air-cooled type uses its own fan for cooling, which has requirements for the environment: such as ventilation, humidity, temperature can not be higher than 40°C, air pH value and so on。Technically, water cooling is 300 to 500 k more efficient than air cooling...

  • 2014-11-13

    Many people do not understand the use of constant temperature and humidity machine at the beginning, in order to avoid unnecessary trouble or laboratory accidents in the process of operating the constant temperature and humidity machine, therefore, for everyone to sort out the precautions for the operation of the brand constant temperature and humidity machine。1.In order to avoid machine failure of many constant temperature and humidity machines, please provide power supply within the rated voltage range。2.In order to prevent electric shock, misoperation and failure, do not switch on the power supply until the constant temperature and humidity machine is installed and connected。3.This product is a non-explosion-proof product, please do not use the constant temperature and humidity machine in the environment with flammable or explosive gases。4.Please try not to open the door panel of the constant temperature and humidity machine during the operation of the instrument. Opening at high temperature may cause burns to the operator. Opening at low temperature may cause burns...